All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/en/packaging/leadfree.html.
Moisture Sensitivity Level Data for LMV712.
A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/en/packaging/greennopb.html.
National's certificate of product compliance for LMV712 is located at RoHS Status.
Reliability Metrics
| Part Number |
Process |
EFR Reject |
EFR Sample Size |
PPM |
LTA Rejects |
LTA Device Hours |
FITS |
MTTF (Hours) |
|
LMV712LD | CS080 | 0 | 30715 | 0 | 0 | 2900500 | 2 | 823024794
|
|
LMV712LDX | CS080 | 0 | 30715 | 0 | 0 | 2900500 | 2 | 823024794
|
|
LMV712MM | CS080 | 0 | 30715 | 0 | 0 | 2900500 | 2 | 823024794
|
|
LMV712MMX | CS080 | 0 | 30715 | 0 | 0 | 2900500 | 2 | 823024794
|
|
LMV712TL | CS080 | 0 | 30715 | 0 | 0 | 2900500 | 2 | 823024794
|
|
LMV712TLX | CS080 | 0 | 30715 | 0 | 0 | 2900500 | 2 | 823024794
|
Note: The Early Failure Rates (EFR) were calculated as point estimate PPM based on rejects and sample size for EFR.
The Long Term Failure Rates were calculated
at 60% confidence using the Arrhenius equation at 0.7eV activation energy and derating the assumed stress
temperature of 150°C to an application temperature of 55°C.
For more information on Reliability Metrics, please click
here.
All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/en/packaging/leadfree.html.
Moisture Sensitivity Level Data for LMV712.
A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/en/packaging/greennopb.html.
National's certificate of product compliance for LMV712 is located at RoHS Status.