National Semiconductor | High-performance Analog

 

 LMV221   

50 MHz to 3.5 GHz 40 dB Logarithmic Power Detector for CDMA and WCDMA from the PowerWise® Family
Click link to Download

Features

  • 40 dB linear in dB power detection range
  • Output voltage range 0.3 to 2V
  • Shutdown
  • Multi-band operation from 50 MHz to 3.5 GHz
  • 0.5 dB accurate temperature compensation
  • External configurable output filter bandwidth
  • 2.2 mm x 2.5 mm x 0.8 mm LLP 6 package
  • Description

    The LMV221 is a 40 dB RF power detector intended for use in CDMA and WCDMA applications. The device has an RF frequency range from 50 MHz to 3.5 GHz. It provides an accurate temperature and supply compensated output voltage that relates linearly to the RF input power in dBm. The circuit operates with a single supply from 2.7V to 3.3V.

    The LMV221 has an RF power detection range from −45 dBm to −5 dBm and is ideally suited for direct use in combination with a 30 dB directional coupler. Additional low-pass filtering of the output signal can be realized by means of an external resistor and capacitor. Figure (a) shows a detector with an additional output low pass filter. The filter frequency is set with RS and CS.

    Figure (b) shows a detector with an additional feedback low pass filter. Resistor RP is optional and will lower the Trans impedance gain (RTRANS). The filter frequency is set with CP//CTRANS and RP//RTRANS.

    The device is active for Enable = High, otherwise it is in a low power consumption shutdown mode. To save power and prevent discharge of an external filter capacitance, the output (OUT) is high-impedance during shutdown.

    The LMV221 power detector is offered in the small 2.2 mm x 2.5 mm x 0.8 mm LLP package.


    Applications

  • UMTS/CDMA/WCDMA RF power control
  • GSM/GPRS RF power control
  • PA modules
  • IEEE 802.11b, g (WLAN)


  • single application with output filter

     

    ParametersValues
    RF Frequency (MHz) 50-3500
    Dynamic Range 40 dB
    Detector Power Range -45 to -5dBm
    Accuracy 0.5 dB
    Inputs/Outputs 1/1
    Transfer Linear in dB
    Modulation Independent No
    Supply Min 2.7 Volt
    Supply Max 3.3 Volt
    Supply Current 7.2 mA
    Shut down Yes
    Detector Ext Coupler, Internal Det
    VCO Freq Range 50MHz to 3.5GHz
    Application CDMA,WCDMA,UTMS,GSM,GPRS,802.11
    Channels 1 Channels
    PLL Type Single
    Temperature Min -40 deg C
    Temperature Max 85 deg C
    PowerWise Yes

    Datasheets
    TitleSizeDateOther
    Language
    LMV221 50 MHz to 3.5 GHz 40 dB Logarithmic Power Detector for CDMA and WCDMA2947
    Kbytes
    28-Mar-08   


    Application Notes
    TitleSizeDateOther
    Language
    AN-1766: Application Note 1766 Evaluation Board for the LMV221 Logarithmic Power Detector335
    Kbytes
    19-Dec-07日本語

    Part Number(s)
    (NSID)
    Top ViewAvailabilityCurrent Reported StockBudgetary PricingPack
    Size
    LMV221SD/NOPB


    RoHS Status


    LLP
    Full production
    Lead Time: 6 weeks

    Samples
    DistributorRegionQty
    ARROWWorldwide544
    AVNET-EMWorldwide11000
    DIGI-KEYWorldwide3128
    FARNELLEurope and Asia600
    MOUSERWorldwide636
    NEWARKAmericas220
    RS COMPONENTSWorldwide1000
    TAYLORAmericas544
    $1.00 each at 1K+ pcsreel
    of
    1000
    LMV221SDX/NOPB


    RoHS Status


    LLP
    Full production
    Lead Time: 6 weeks

     
    DistributorRegionQty
    DIGI-KEYWorldwide0
    $1.00 each at 1K+ pcsreel
    of
    4500

    All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/en/packaging/leadfree.html.

    Moisture Sensitivity Level Data for LMV221.

    A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/en/packaging/greennopb.html.

    National's certificate of product compliance for LMV221 is located at RoHS Status.

    Part Number(s)
    (NSID)
    DescriptionAvailabilityCurrent Reported StockBudgetary PricingPack
    Size
    LMV221EVAL/NOPB

    LMV221 Logarithmic Power Detector Evaluation BoardFull production
    Lead Free (RoHS)

     
    DistributorRegionQty
    DIGI-KEYWorldwide0
    $99.00 each1

    This evaluation board is designed to aid in the characterization of National Semiconductor`s LMV221 Logarithmic Power Detector. This board simplifies the measurement of the DC output voltage that the LMV221 produces in response to the power level of the RF signal applied to the RF input. Use the evaluation board as a guide for high frequency layout and as a tool to aid in device testing and characterization.

    Contents:




    National Semiconductor follows the provisions of the Product Stewardship Guide for Customers (CSP-9-111C1) and Banned Substances and Materials of Interest Specification (CSP-9-111S2) for regulatory environmental compliance. Details may be found at: www.national.com/en/packaging/greennopb.html. Lead free products are RoHS compliant.

    Lead Free product status is available through the search tool located here

    Part Number(s)
    (NSID)
    Weight
    (milligrams)
    TypePinsMSL RatingPeak ReflowRoHS
    Status
    CAD SymbolsModelsPackage
    Marking
    Format
    LMV221SD/NOPB

    11.721
    LLP61260DetailN/AN/A
    XTT
    A96
    LMV221SDX/NOPB

    11.721
    LLP61260DetailN/AN/A
    XTT
    A96

    All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/en/packaging/leadfree.html.

    Moisture Sensitivity Level Data for LMV221.

    A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/en/packaging/greennopb.html.

    National's certificate of product compliance for LMV221 is located at RoHS Status.

    CAD Symbols and Models
    N/A
     Models
    N/A


    Reliability Metrics
    Part Number Process EFR Reject EFR Sample Size PPM LTA Rejects LTA Device Hours FITS MTTF (Hours)
    LMV221SDBICMOS8B+036320027622922783807897
    LMV221SDXBICMOS8B+036320027622922783807897

    Note: The Early Failure Rates (EFR) were calculated as point estimate PPM based on rejects and sample size for EFR. The Long Term Failure Rates were calculated at 60% confidence using the Arrhenius equation at 0.7eV activation energy and derating the assumed stress temperature of 150°C to an application temperature of 55°C.

    For more information on Reliability Metrics, please click here.


    All information pertaining to the RoHS Compliance Standard can be found at http://www.national.com/en/packaging/leadfree.html.

    Moisture Sensitivity Level Data for LMV221.

    A RoHS compliance or an IPC 1752 report can be acquired at http://www.national.com/en/packaging/greennopb.html.

    National's certificate of product compliance for LMV221 is located at RoHS Status.

    [Information as of 9-Feb-2012]