Datasheet
Featured Application Notes
More Application Notes
Reliability Metrics
| Part Number |
Process |
EFR Reject |
EFR Sample Size |
PPM |
LTA Rejects |
LTA Device Hours |
FITS |
MTTF (Hours) |
|
LMP2016MA | CS080 | 0 | 30535 | 0 | 0 | 2810500 | 2 | 797458048
|
|
LMP2016MAX | CS080 | 0 | 30535 | 0 | 0 | 2810500 | 2 | 797458048
|
|
LMP2016MM | CS080 | 0 | 30535 | 0 | 0 | 2810500 | 2 | 797458048
|
|
LMP2016MME | CS080 | 0 | 30535 | 0 | 0 | 2810500 | 2 | 797458048
|
|
LMP2016MMX | CS080 | 0 | 30535 | 0 | 0 | 2810500 | 2 | 797458048
|
Note: The Early Failure Rates (EFR) were calculated as point estimate PPM based on rejects and sample size for EFR.
The Long Term Failure Rates were calculated
at 60% confidence using the Arrhenius equation at 0.7eV activation energy and derating the assumed stress
temperature of 150°C to an application temperature of 55°C.
For more information on Reliability Metrics, please click
here.