Datasheet
Package Availability, Models, Samples & Pricing
General Description
The LMH0046 HD/SD SDI Reclocker retimes serial digital video data conforming to the SMPTE 292M and SMPTE 259M (A & C) standards.
The LMH0046 operates at serial data rates of 143 Mbps, 270 Mbps, 1.483 Gbps and 1.485 Gbps. The LMH0046 supports DVB-ASI operation
at 270 Mbps.
The LMH0046 automatically detects the incoming data rate and adjusts itself to retime the incoming data to suppress accumulated
jitter. The LMH0046 recovers the serial data-rate clock and optionally provides it as an output. The LMH0046 has two differential
serial data outputs; the second output may be selected as a low-jitter, data-rate clock output. Controls and indicators are:
serial clock or second serial data output select, manual rate select input, SD/HD rate indicator output, lock detect output,
auto/manual data bypass and output mute. The serial data inputs, outputs, and serial data-rate clock outputs are differential
LVPECL compatible. The CML serial data and serial data-rate clock outputs are suitable for driving 100Ω differentially terminated
networks. The control logic inputs and outputs are LVCMOS compatible.
The LMH0046 is powered from a single 3.3V supply. Power dissipation is typically 330 mW. The device is housed in a 20-pin
e-TSSOP package.
Reliability Metrics
| Part Number |
Process |
EFR Reject |
EFR Sample Size |
PPM |
LTA Rejects |
LTA Device Hours |
FITS |
MTTF (Hours) |
|
LMH0046MH | BICMOS8B+ | 0 | 1152 | 0 | 0 | 743900 | 5 | 211083656
|
|
LMH0046MHX | BICMOS8B+ | 0 | 1152 | 0 | 0 | 743900 | 5 | 211083656
|
Note: The Early Failure Rates (EFR) were calculated as point estimate PPM based on rejects and sample size for EFR.
The Long Term Failure Rates were calculated
at 60% confidence using the Arrhenius equation at 0.7eV activation energy and derating the assumed stress
temperature of 150°C to an application temperature of 55°C.
For more information on Reliability Metrics, please click here.
Application Notes
| Title | Size in Kbytes |
Date |
 |
| AN-2004: Application Note 2004 Replacing the CLC016 Reclocker with the LMH0026 |
154 Kbytes |
13-Oct-09 |
Download |
More Application Notes
| Title | Size in Kbytes |
Date |
 |
| AN-2002: Application Note 2002 Replacing the CLC014 Adaptive Cable Equalizer with the LMH0074 |
158 Kbytes |
22-Sep-09 |
Download |
| AN-2003: Application Note 2003 Replacing the CLC012 Adaptive Cable Equalizer with the LMH0074 |
160 Kbytes |
6-Oct-09 |
Download |
[Information as of 8-Nov-2009]
|