ΣΔ ADC architecture
|
| |
Monitors 9 power supplies
|
| |
Monitors 4 remote thermal diodes and 2 LM60
|
| |
New TruTherm technology support for precision thermal diode measurements
|
| |
Internal ambient temperature sensing
|
| |
Programmable autonomous fan control based on temperature readings with fan boost support
|
| |
Fan boost support on tachometer limit error event
|
| |
Fan control based on 13-step lookup table or PI Control Loop or combination of both
|
| |
PI fan control loop supports Tcontrol
|
| |
Temperature reading digital filters
|
| |
0.5°C digital temperature sensor resolution
|
| |
0.0625°C filtered temperature resolution for fan control
|
| |
2 PWM fan speed control outputs
|
| |
4 fan tachometer inputs
|
| |
Processor thermal throttling (
^PROCHOT) monitoring
|
| |
Dynamic VID monitoring (6/7 VIDs per processor) supports VRD10.2/11
|
| |
8 general purpose I/Os:
| |
4 can be configured as fan tachometer inputs
|
| |
2 can be configured to connect to processor
^THERMTRIP
|
| |
2 are standard GPIOs that could be used to monitor
^IERR signal
|
|
| |
A general purpose inputs that can be used to monitor the 7th VID signal for VRD11
|
| |
Limit register comparisons of all monitored values
|
| |
2-wire serial digital interface, SMBus 2.0 compliant
| |
Supports byte/block read and write
|
| |
Selectable slave address (tri-level pin selects 1 of 3 possible addresses)
|
| |
^ALERT output supports interrupt or comparator modes
|
|
| |
LLP-48 package
|
| |
XOR-tree test mode
|