Datasheet
Package Availability, Models, Samples & Pricing
General Description
The LM5088 high voltage non-synchronous buck controller features all the necessary functions to implement an efficient high
voltage buck converter using a minimum number of external components. The LM5088 can be configured to operate over an ultra-wide
input voltage range of 4.5V to 75V. This easy to use controller includes a level shifted gate driver capable of controlling
an external N-channel buck switch. The control method is based upon peak current mode control utilizing an emulated current
ramp. The use of an emulated control ramp reduces noise sensitivity of the pulse-width modulation circuit, allowing reliable
control of very small duty cycles necessary in high input voltage/low output voltage applications. The LM5088 switching frequency
is programmable from 50 kHz to 1 MHz.
The LM5088 is available in two versions: The LM5088-1 provides a +/-5% frequency dithering function to reduce the conducted
and radiated EMI, while the LM5088-2 provides a versatile restart timer for overload protection. Additional features include
a low dropout bias regulator, tri-level enable input to control shutdown and standby modes, soft-start and oscillator synchronization
capability. The device is available in a thermally enhanced TSSOP-16EP pin package.
Reliability Metrics
| Part Number |
Process |
EFR Reject |
EFR Sample Size |
PPM |
LTA Rejects |
LTA Device Hours |
FITS |
MTTF (Hours) |
|
LM5088MH-1 | ABCD150XV1 | 0 | 3868 | 0 | 0 | 2595000 | 2 | 736338335
|
|
LM5088MH-2 | ABCD150XV1 | 0 | 3868 | 0 | 0 | 2595000 | 2 | 736338335
|
|
LM5088MHX-1 | ABCD150XV1 | 0 | 3868 | 0 | 0 | 2595000 | 2 | 736338335
|
|
LM5088MHX-2 | ABCD150XV1 | 0 | 3868 | 0 | 0 | 2595000 | 2 | 736338335
|
Note: The Early Failure Rates (EFR) were calculated as point estimate PPM based on rejects and sample size for EFR.
The Long Term Failure Rates were calculated
at 60% confidence using the Arrhenius equation at 0.7eV activation energy and derating the assumed stress
temperature of 150°C to an application temperature of 55°C.
For more information on Reliability Metrics, please click here.
Design Tools
| Title | Size in Kbytes |
Date |
 |
|
|
| LM(2)5088 Quick Start Calculator |
268 Kbytes |
5-Dec-2008 |
View |
|
|
Application Notes
| Title | Size in Kbytes |
Date |
 |
| AN-1913: Application Note 1913 LM5088 Evaluation Board |
246 Kbytes |
9-Dec-08 |
Download |