LM7912 - 3-Terminal Negative Regulator
Datasheet Packaging Samples & Pricing Reliability Knowledge Base

Features
Thermal, short circuit and safe area protection
High ripple rejection
1.5A output current
4% tolerance on preset output voltage

General Description


The LM79XX series of 3-terminal regulators is available with fixed output voltages of -5V, -12V, and -15V. More...


  Typical Application
click for larger image


ParametersValues
Output Current 1500 mA
Output Min -12 Volt
Input Min Voltage -35 Volt
Input Max Voltage -14.5 Volt
Adjustable Output No
On/Off Pin No
Error Flag No
RegType Linear Regulator
Temperature Min 0 deg C
Temperature Max 125 deg C
Output Max -12 Volt
Output Voltage -12 Volt

  Connection Diagram
*click for larger image



Datasheet
RoHS Compliance Information Size in KbytesDate Click link below to Download
LM79XX Series 3-Terminal Negative Regulators 154
Kbytes
7-Sep-01 Download

If you have trouble printing or viewing PDF file(s), see Printing Problems.


Package Availability, Models, Samples & Pricing
Part NumberPackageFactory Lead TimeModelsSamples &
Electronic
Orders
Budgetary PricingStd
Pack
Size
Package
Marking
Format
TypePinsSpec.MSL
Rating
Peak
Reflow
RoHS
Report
CAD
Symbols
WeeksQtyQty$US each
LM7912CTTO-2203NOPB
STD
1
1
NA
NA
RoHS N/A Full productionN/A
Samples
Buy Now
1K+$0.62rail
of
45
NSUZXYTTE#
LM7912CT
8 weeks2000

General Description


The LM79XX series of 3-terminal regulators is available with fixed output voltages of -5V, -12V, and -15V. These devices need only one external component-a compensation capacitor at the output. The LM79XX series is packaged in the TO-220 power package and is capable of supplying 1.5A of output current.

These regulators employ internal current limiting safe area protection and thermal shutdown for protection against virtually all overload conditions.

Low ground pin current of the LM79XX series allows output voltage to be easily boosted above the preset value with a resistor divider. The low quiescent current drain of these devices with a specified maximum change with line and load ensures good regulation in the voltage boosted mode.

For applications requiring other voltages, see LM137 datasheet.

Reliability Metrics


Part Number Process EFR Reject EFR Sample Size PPM LTA Rejects LTA Device Hours FITS MTTF (Hours)
LM7912CTSLM04404600353250011002356520

Note: The Early Failure Rates (EFR) were calculated as point estimate PPM based on rejects and sample size for EFR. The Long Term Failure Rates were calculated at 60% confidence using the Arrhenius equation at 0.7eV activation energy and derating the assumed stress temperature of 150°C to an application temperature of 55°C.

For more information on Reliability Metrics, please click here.