Korean Chinese Traditional Chinese Simplified Japanese


EOS/ESD INFORMATION

Return to Cause and Effect menu   Go to the Effects section Go to the Causes section Currently in the Sources section Go to the Methods of Investigation section

 Junction Damage: Sources   (What generated the voltage spike?)
Humans   Description   Investigate
Handling by un-grounded personnel
  • Insufficient training or certificate program
  • Uncontrolled work flows / processes
  • Current procedures or practices not ESD compliant
Machine Design PCB design and layout with ESD suppression
Improperly grounded
  • All components contacting IC or PCBs must be conductive and connected to ground
  • All components contacting IC or PCBs must be conductive and equi-potential to ground (ie. Phenolic spacers in a handler; Suspect any non-metallic piece
  • Soldering Irons (ie. Too high resistance of tip to ground; Three prong electrical plug.
Ground bounce sources Switching relays
Field Inductance or EMI Arcing; CRT related items; Electric motors; Microwave sources, RF sources
Cleanliness of raw power supply
Noisy supply from external supplier Monitor Electric utility
Network load variations Ground bounce sources; Voltage Supply harmonics; Switching relays
Environment
Weather Lightning strikes; Low humidity (<40RH)
Triboelectric materials Non-conductive table tops, wall panels, floor. Packing & transport materials. Styrofoam coffee cups.
Resistive ground references ESD ground common with facility ground
Manufacturing defects
Inherent design weakness circuit design; layout
Silicon defect crystalline; particulates
 

Return to Cause and Effect menu   Go to the Effects section Go to the Causes section Currently in the Sources section Go to the Methods of Investigation section